Omron CP - PROGRAMMING MANUAL 05-2007 Programming Manual page 757

Cp1h/cp1l cpu unit
Table of Contents

Advertisement

High-speed Counter/Pulse Output Instructions
Operand Specifications
724
15
12
11
8
M
Pulse output method (See note.)
Always 0 hex.
Note: Use the same pulse output method when using both pulse outputs 0 and 1 (CP1H only).
F: First Pulse Frequency Word
The value of F and F+1 sets the pulse frequency in Hz.
15
F
Lower word of target frequency
Upper word of target frequency
F+1
Note
The maximum frequency that can be specified depends on the model and
pulse output support. Refer to the CP1H Operation Manual.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
Indirect DM addresses
in binary
Indirect DM addresses
in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
7
4
3
0
Mode
0 hex: Continuous
1 hex: Independent
Direction
0 hex: CW
1 hex: CCW
0 hex: CW/CCW
1 hex: Pulse + direction
0
0 to 1,000,000 Hz (See note.)
(0000 0000 to 000F 4240 hex)
P
---
---
---
---
---
---
---
---
---
See descrip-
tion of oper-
and.
---
---
---
Section 3-20
M
---
CIO 0 to CIO 6142
---
W0 to W510
---
H0 to H510
---
A448 to A958
---
T0000 to T4094
---
C0000 to C4094
---
D0 to D32766
---
@ D0 to @ D32767
---
*D0 to *D32767
See descrip-
See description of oper-
tion of oper-
and.
and.
---
---
---
---
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to
–2048 to +2047 ,IR15
DR0 to DR15, IR0 to
IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
F

Hide quick links:

Advertisement

Table of Contents
loading