High-speed Counter/Pulse Output Instructions
Operation
Purpose
Application
Starting
To output
Accelerat-
pulse out-
with speci-
ing the
put
fied accel-
speed (fre-
eration
quency) at a
and speed
fixed rate
Changing
To change
Changing
settings
speed
the speed
smoothly
smoothly
during oper-
ation
Changing
the speed in
a polyline
curve during
operation
Stopping
while
changing
the speed
742
• If the difference between the starting speed and target speed is be-
tween 200 and 300 KHz, the acceleration/deceleration rate will be 3 Hz
or higher.
.
. .
.
• If the difference between the starting speed and target speed is be-
tween 900 and 1,000 KHz, the acceleration/deceleration rate will be 10
Hz or higher.
Continuous Mode Speed Control
Pulse output will continue until it is stopped from the program.
Note
Pulse output will stop immediately if the CPU Unit is changed to PROGRAM
mode.
Frequency changes
Pulse frequency
Target frequency
Present frequency
Execution of ACC(888)
Pulse frequency
Target frequency
Present frequency
Execution of ACC(888)
Pulse frequency
Target frequency
Present frequency
Execution of ACC(888)
Execution of ACC(888)
Pulse frequency
Present frequency
Target frequency = 0
Acceleration/
deceleration
rate
Time
Acceleration/
deceleration
rate
Time
Acceleration rate n
Acceleration
rate 2
Acceleration
rate 1
Time
Execution of ACC(888)
Acceleration/
deceleration rate 1
Acceleration/
deceleration rate 2
Time
Execution of
ACC(888) Execution of
ACC(888)
Execution of ACC(888)
(target frequency = 0)
Section 3-20
Description
Procedure/
instruction
Outputs pulses and
ACC(888) (Con-
changes the frequency
tinuous)
at a fixed rate.
Changes the frequency
ACC(888) or
from the present fre-
SPED(885)
quency at a fixed rate.
(Continuous)
The frequency can be
accelerated or deceler-
ACC(888) (Con-
ated.
tinuous)
Changes the accelera-
ACC(888) (Con-
tion or deceleration rate
tinuous)
during acceleration or
deceleration.
ACC(888) (Con-
tinuous)
The deceleration rate is
ACC(888) (Con-
changed while stopping.
tinuous)
Note When the target
frequency is
ACC(888) (Con-
changed to 0 Hz,
tinuous)
the current decel-
eration rate will
ACC(888) (Con-
continue to be
tinuous, target
used.
frequency of 0)