Display Instructions

3-25 Display Instructions
3-25-1 DISPLAY MESSAGE: MSG(046)
Purpose
Ladder Symbol
Variations
Applicable Program Areas
Operands
Operand Specifications
15
8 7
C:
D200
0
0
0
C+1:
D201
0
0
0
C+2:
D202
0
6
1
C+3:
D203
0
0
0
C+4:
D204
0
0
0
This section describes instructions used to display messages.
Instruction
DISPLAY MESSAGE
SEVEN-SEGMENT LED
WORD DATA DISPLAY
SEVEN-SEGMENT LED CON-
TROL
Reads the specified sixteen words of extended ASCII and displays the mes-
sage on the Programming Device.
MSG(046)
N
M
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported.
Immediate Refreshing Specification
Block program areas
OK
OK
N: Message number
The message number must be 0000 to 0007 hexadecimal (or 0 to 7 decimal).
M: First message word
When displaying a message, M specifies the address of the first of the words
containing the ASCII message. When clearing a message, M can be any
hexadecimal constant (0000 through FFFF).
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
0
7
Node address of remote CPU Unit to be written to = 07 hex (node 07)
3
Write data size (number of words) = 3 hex
Communications port = 6 hex (port 6),
2
and the DeviceNet Unit's unit address = 12 hex
0
Response monitoring time = 0000 hex (2 s)
0
Explicit format type = 0000 hex (DeviceNet format)
Mnemonic
MSG
SCH
SCTRL
N: Message number
M: First message word
Step program areas
Subroutines
OK
M
CIO 0 to CIO 6143
W0 to W511
H0 to H511
A0 to A959
Section 3-25
Function
Page
code
046
911
047
913
048
915
MSG(046)
@MSG(046)
Not supported.
Interrupt tasks