Download Print this page

Reinstalling The Pms - Viking VSS2249RQ User Manual

Advertisement

4. Push the module into the enclosure until the lock bar engages and the
5. Push the lock bar upward to cam the server module into the enclosure.
6. Tighten the thumbscrew to secure the module in place. The thumbscrew
7. Install the appropriate cables into their corresponding ports on the server
8. Repeat steps 1 through 7 to install the remaining server module.
9. Server module reinstallation is complete.

REINSTALLING THE PMS

1. Ensure the PM is in the proper orientation with the PM release tab at the
2. With one hand supporting the bottom of the first PM, insert the first PM
3. Fully push the PM into the enclosure until the PM release tab engages
4. Test to ensure the PM is properly installed. Pull the finger handle slightly
5. Repeat steps 1 through 4 for the remaining PM to complete installation.
| 44 |
module is flush with the face of the enclosure. Never force the module
into place.
locations are also pictured in Figure 4.4 on page 33.
module operator panel.
See the section titled "Server Module Operator Panel" that begins on page 24 for
guidance in cable connection.
WARNING: At this point in installation, the system should not be connected to a power
source. There is no power switch on this unit. Once the first power cord is connected to
an active PDU, the system starts. If this system has been powered up, two power
cords must be unplugged from the PDU receptacle to properly shut down the chassis.
ESD-SENSITIVE DEVICE. Only install the device on a properly grounded electrostatic
discharge (ESD) protection surface to avoid damage to the components. Always utilize
a properly grounded ESD wrist strap or mat during operation or installation of the
device, or when connecting the cables.
WARNING: While some factory-approved maintenance on FRUs (e.g. hot-swapping a
PM, SSD, or server module) does not require the user to disconnect power to the
system, performing other types of maintenance on systems connected to an electrical
power source may result in serious injury or death. Only individuals with knowledge
and training in working with devices containing live circuits should operate the system.
Take precautions when performing all other types of maintenance. Disconnect 2
power supply cords before servicing.
top. Figure 4.7 on page 35 identifies the release tab and finger handle.
into the power cavity on the rear of the enclosure.
and the PM cams into place.
outward to verify the PM is locked in place. If the PM can be easily
removed from the enclosure without pushing the PM release tab, remove
the PM and repeat steps 2 and 3, and then retest installation.
Chapter 4: Installing the Enclosure Into a Rack
CTC-DOC-002293, Rev A.2

Advertisement