Monitoring
Temperature
Fans
PSUs
Event reporting through IPMI
Secure management access
Reporting
Physical Design
Rack Specification
Chassis length—Front surface to rear
surface (excluding CMA)
Overall length - Front bezel to edge of
CMA baskets
Depth - Vertical rail to rear surface
Serviceable position pull length
Rail depth
Rack envelope
Enclosure width
Front width w/o rack ears
Height
| 124 |
Up to 2 TB memory supported
4 GB to 128 GB DIMMs
2x internal type M M.2 SSDs
4x PCIe® Gen 4 x16 slots for HHHL add-in card
ASPEED® AST2500 (video) iBMC
1 GbE (BMC) and NTB (host)
4x lanes PCIe Gen 3 NTB
Out-of-band mgmt via MegaRAC® BMC WebUI
2x USB 3.1 Gen 1 (5 Gb/s) type A
1x USB Mini-B serial console only
128x lanes PCIe
2x 32MB SPI2 Flash
IPMI v2.1, support for Redfish®
Virtual UART for serial-over-LAN
PMs
2x 1600W PMs
N+1 redundant
Support for AC and DC option, CRPS form factor
Additional capacities available based on SSD or
add-in card requirements
Different PSU CRPS form factors may require a
change in the power adapter board.
Logging into the data center
Serial and part numbers, enclosure and server
module revisions
EIA-310-D 19-in. (48.3cm) 2U high
67.6 cm (26.7 in.)
98.7 cm (38.9 in.)
69.7 cm (27.5 in.)
34.1 cm (13.4 in.)
From: 76.2 cm (30.0 in.) To: 94.0 cm (37.0 in.)
1.0 m (39.4 in.)
48.3 cm (19.0 in.)
43.8 cm (17.3 in.)
8.7 cm (3.5 in.)
Appendix A: Product Specifications
CTC-DOC-002293, Rev A.2