REDUCING SYSTEM WEIGHT

If all FRU components arrive preinstalled, removing them from the enclosure
may be necessary to reduce system weight before installing the enclosure into
the rack. Removing these FRUs can reduce the total weight by as much as 29.2
pounds (13.3 kilograms). This section provides instructions on removing the
FRU components to minimize system weight for rack installation.
3877
CTC-DOC-002293, Rev A.2
24 drive carrier assemblies with drives or drive blanks preinstalled in

the drive carriers
NOTE: Viking Enterprise Solutions recommends that disk drives acclimate to room
temperature for two hours prior to installation.
Accessories:

Interface cables (if ordered)

Rail kit:
One left adjustable rack mounting rail (marked LEFT)

One right adjustable rack mounting rail (marked RIGHT)

Rail installation hardware

Four M4 X 4 Phillips® screws (two for rack installation and two

spares)
Eight #10 32 X 14.5 (7.1mm) round hole rack screws

Two M5 X 9 Phillips shipping screws

See the section titled "Contact Information" that begins on page 207 for
instructions on contacting a Viking Enterprise Solutions sales representative to
inquire about any missing components.
To skip the weight reduction instructions, proceed to "Enclosure Rack Installation"
on page 35.
To view the system weight table, refer to the section titled "Weights" that begins
on page 127 of Appendix A.
CAUTION: These instructions assume the enclosure and drives are being installed for
the first time, and the enclosure has not yet been connected to a power source. If
replacing or hot-swapping a FRU, proceed to Chapter 8 titled "System Maintenance"
that begins on page 93 for instructions.