2. Lift the release handle fully open as shown in Figure 4.2 and gently
3. Grab the carrier frame above and below the release handle as shown in
4. Place the drive carrier assembly on an anti-static surface until
5. Repeat steps 1 through 4 to remove the remaining drive carrier
6. Drive carrier removal is complete.

Removing Server Modules

Removing the VSSEP1EC Server Modules may be necessary during rack
installation to minimize weight. The following instructions describe how to
remove the server modules from the enclosure.
1. Loosen the thumbscrew securing the first server module to the
Figure 4.4 Server module thumbscrew and lock bar
2. Pull the lock bar downward to release the cam from the locked position.
CTC-DOC-002293, Rev A.2
begin to remove the drive carrier from the drive bay by gently pulling the
middle of the handle. Use care to avoid damaging the release latch
identified in Figure 4.3.
Figure 4.3 and pull the drive carrier assembly completely out of the bay.
reinstallation.
assemblies from the enclosure.
ESD-SENSITIVE DEVICE. Only install the device on a properly grounded electrostatic
discharge (ESD) protection surface to avoid damage to the components. Always utilize
a properly grounded ESD wrist strap or mat during operation or installation of the
device, or when connecting the cables.
enclosure. The thumbscrew is identified in Figure 4.4.
Lock bar
The lock bar motion is demonstrated in Figure 4.5 on page 34.
VSS2249RQ Storage Server User Guide
Thumbscrew