Enclosure Extension; Bezel Removal - Viking VSS2249RQ User Manual

Advertisement

Figure 8.3 Bezel removal
2. Slide the two retention tabs out of the slots in the top of the right rack ear
3. Lift the bezel away from the enclosure.

Enclosure Extension

Replacing system fan modules requires that the enclosure is extended from the
rack in the serviceable position. The hot-swappable PMs and server modules
are hot aisle service items and do not require the enclosure to be extended from
the rack for service.
| 96 |
Bezel left underside
Left rack ear
identified in Figure 8.3.
If replacing a PM or server module, skip this section and proceed to page 98 for
instructions on releasing the CMA.
HEAVY OBJECT: This system weighs approximately 56.2 pounds (25.5 kilograms)
when all 24 drives, two PMs, and two server modules are preinstalled. To prevent
personal injury and equipment damage, always obtain assistance during rack
installation and when sliding the system in or out of the rack.
TIPPING HAZARD— Prevent instability and hazardous conditions due to uneven loading
by installing heavier items into the bottom of the equipment rack and lighter items into the
top.
Chapter 8: System Maintenance
Right rack ear
CTC-DOC-002293, Rev A.2