WARNING: Hot-swapping FRUs must be completed within five (5) minutes to ensure
proper system cooling and prevent damage to the drives. Individual drive temperature
monitoring is not currently supported.
CAUTION: Take precautions before connecting the enclosure to a power supply to
ensure that the equipment does not overload circuits, or negatively impact over-current
protection and supply wiring. Check the equipment nameplate ratings when addressing
power concerns.
TIPPING HAZARD—Prevent instability and hazardous conditions due to uneven loading
by installing heavier items into the bottom of the equipment rack and lighter items into the
top.
CAUTION: Place the equipment rack in a dust-free, well-ventilated area close to an
appropriate power source that is protected by a uninterruptible power supply (UPS).
Leave enough room behind the rack for servicing and to allow sufficient airflow from front
to back.
CAUTION: Two server modules must be installed to ensure proper system cooling.
Running the system without both modules can cause the drives to overheat.
HEARING PROTECTION: This enclosure produces 78 dB levels of sound power at 60%
of power during normal operation. The acoustic sound power increases to 85.5dB at
100% power under fault conditions. Prolonged periods of high sound levels may be
potentially harmful. Use of hearing protection is recommended.
NOTE: For equipment racks with single or multiple storage subsystems installed, the typical
TMRA (manufacturer's maximum recommended ambient) is 35°C (95°F). (Refer to the
product user guide to obtain the actual TMRA for the product.) When installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment may
be greater than the room ambient; therefore, consideration should be given to installing the
equipment in an environment compatible with the manufacturer's maximum recommended
ambient temperature.
NOTE: To obtain a copy of the product user guide, email
customersupport@vikingenterprise.com.
NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference; and (2) This
device must accept any interference received, including interference that may cause
undesired operation.