TEMPERATURE, HUMIDITY, & ALTITUDE
At the time of publication, thermal testing was still in progress. The anticipated environmental
specifications for system temperature, RH, and altitude are presented in the following tables.
Operating Environment
Temperature range
Relative humidity
Altitude
*. Maximum operating temperature is specified at sea level and is derated 2 percent per 305 m
Non-operating Environment
Temperature range
Relative humidity
Altitude
Transit Conditions Storage Environment
Temperature range
Relative humidity
Altitude
Temperature range
Relative humidity
Altitude

SOUND POWER

Acoustics
Acoustic levels are not anticipated to exceed an A-weighted sound power of 7.4 Bels at idle/
active operation and have been tested to ISO 7779. The acoustic sound level is expected to
increase to 8.4 Bels under fault conditions.
PACKAGING & TRANSPORTATION
The VSS2249RQ Storage Server's packaging is designed to meet ISTA Procedure 1A 01-06 for
single packaging and ISTA Procedure 1E 05-07 for pallet shipping.
| 126 |
(1,000 ft) of increased altitude
HEARING PROTECTION: This enclosure produces 78 dB levels of sound power at
60% of power during normal operation. The acoustic sound power increases to
85.5dB at 100% power under fault conditions. Prolonged periods of high sound
levels may be potentially harmful. Use of hearing protection is recommended.
Appendix A: Product Specifications
*
5°C (41°F) to 35°C
(95°F)
20% to 80% non-condensing
-61 m ft (-200) to 3,048 m (10,000 ft)
5°C (41°F) to 45°C (113°F)
10% to 90% non-condensing
-61 m (-200 ft) to 3,048 m (10,000 ft)
-40°C (-40°F) to 60°C (140°F)
10% to 90% non-condensing
-61 m (-200 ft) to 12,192 m (40,000 ft)
1°C (34°F) to 60°C (140°F)
10% to 80% non-condensing
-61 m (-200 ft) to 3,048 m (10,000 ft)