3745 Alert Reference Code2F
Alert Condition: An error was detected at IPL time which prevented the adapter from being
operational after IPL completion.
ALARM 2F : HARDWARE ERROR: ELAyy (PORT 1-2) IML FAILED
~
NetView· Alert· Dynamic
Adapter Error: Local CSMA/CD Adapter
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X' FDA9DED9 '
SV
X'92'
Alert Type
X'01'
Permanent
SV
X'92'
Alert Description
X'1010'
Adapter error
SV
X'92'
Probable Causes
X'3322'
Local
CSMA/CD
adapter
SV
X'93'
User Causes
(none)
SV
X'94'
SF
X'01'
Install Causes
X'1500'
Mismatch between hardware and microcode
SV
X'95'
SF
X'01'
Actions
X'1503'
Correct configuration
SV
X'95'
SF
X'81'
Failure Causes
X'3322'
Local
CSMA/CD
adapter
SV
X'96'
SF
X'01'
X '0201'
I nternal power unit
Actions
X'0200'
Check power
SV
X'96'
SF
X'81'
X'3000'
Contact Appropriate Service Representative
X' FOAO'
for
X'82' SF-
(Controller ID (x'69'))
'3745'
X'32CO'
Report the following:
X'82' SF
(Adapter number (x'61')) 'yy'
X'82' SF
(Reference Code (x'30'))
X'00B1'
Perform Problem Determination Procedure
at reporting location for
X'82'SF
(Product Alert Reference Code (x'FO'))
'2F'
X'2203'
Review supporting data at Alert Sender
Alerts
Chapter 1. Alarms and Alerts
1-75

Advertisement

Table of Contents
loading

Table of Contents