IBM 3745 Problem Determination Manual page 138

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
Alerts
3745 Alert Reference Code 83
Alert Condition: The tOken-ring multiplex card caused an error at the direct-memory-access level or
interrrupt level.
ALARM 83 : TRSS HARDWARE ERROR: TRA xx DOWN (TIC 1-2)
Adapter Error: Local Token Ring Adapter
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X'34AB3171,
SV X'92'
Alert Type
X'01'
Permanent
SV X'92'
Alert Description
X'1010'
Adapter Error
SV X'92'
Probable Causes
X '3320'
Local TOken-Ring Adapter
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X'3320'
Local Token Ring Adapter
SV X'96' SF X'01'
X'3220'
Local Token Ring Adapter Interface
X '0003'
Processor Switch (Models
210, 310,410,
and
610)
Actions
X'13A1'
Reactivate resources attached to
SV X'96' SF X'81'
X'82'
SF
(Line Adapter Number (x'63'))
X'3300'
If problem re-occurs then do the following
X'3000'
Contact Appropriate Service Representative
X'32CO'
Report the -following:
X'82'
SF
(Reference Code (x'30')),
X'82'
SF
(Product Alert Reference Code (x'FO'))
X'2203'
Review supporting data at Alert Sender
Chapter 1. Alarms and Alerts
1--121

Advertisement

Table of Contents
loading

Table of Contents