IBM 3745 Problem Determination Manual page 157

Communication controller
Table of Contents

Advertisement

. . . . .
-.---
•.
-~---
....
- . - . -
...
-
.................
-
........
-------.--.-
......•....
------~
Alerts
3745 Alert Reference Code AS
Alert Condition: The power control unit has detected that the battery voltage (feeding the time-of-day
logic) was below a defined threshold.
MOSS Console Alarm Message
--------------~~------------.
ALARM AS : ASK SERVICE PERSONNEL TO REPLACE BATTERY
~
NetView' Alert· Dynamic
Loss of Electrical Power: MOSS Battery
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X '62BBC7 A9 '
SV X'92'
Alert Type
X'11'
Impending
SV X'92'
Alert Description
X'1400'
Loss of Electrical Power
SV X'92'
Probable Causes
X'0211 '
MOSS Battery
SV X'93'
User Causes
(none).
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X '02111
MOSS Battery
SV X'96' SF X'01'
X"0202'
Internal Power Control Unit
Actions
X'3000'
Contact Appropriate Service Representative
SV X'96' SF X'81'
X ' 32CO'
Report the following:
X ' 82 1
SF
(Reference Code (x'30'»
X'82'
SF
(Product Alert Reference Code (x'FO'))
1-140
IBM 3745 Communication Controller: Problem Determination Guide
o
("'\
~)
o

Advertisement

Table of Contents
loading