IBM 3745 Problem Determination Manual page 137

Communication controller
Table of Contents

Advertisement

Alerts
3745 Alert Reference Code 82
Alert Condition: A permanent token-ring input/output error (CCU
liD
bus) has been detected by the
CCU/control
program or there has been an adapter error.
MOSS Console Alarm Message - - - - - - - - - - - - - - - - - - - - ' - - - - - - - .
ALARM 82 : TRSS HARDWARE ERROR: TRA xx DISCONNECTED
Adapter Error: Local Token Ring Adapter
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X'34AB3171,
SV X'92'
Alert Type
X'01'
Permanent
SV X'92'
Alert Description
X'1010'
Adapter Error
SV X'92'
Probable Causes
X'3320'
Local Token-Ring Adapter
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install
Cause~
(none)
SV X'9S' SF X'01'
Failure Causes
X'3320'
Local Token Ring Adapter
SV X'96' SF X'01'
X'3220'
Local Token Ring Adapter Interface
X'OOO3'
Processor Switch (Models
210, 310,410,
and
610)
Actions
X'13A1'
Reactivate resources attached to
SV X'96' SF X'81'
X'82'
SF
(Line Adapter Number (x'63'))
X'3300'
If problem re-occurs then do the following
X'3000'
Contact Appropriate Service
Representativ~
X'32CO'
Report the following:
X'82'
SF
{Reference Code (x'30'))
X'82'
SF
(Product Alert Reference Code (x'FO'))
X'2203'
Review supporting data at Alert Sender
1-120
IBM 3745 Communication Controller: Problem Determination Guide
o
o

Advertisement

Table of Contents
loading

Table of Contents