IBM 3745 Problem Determination Manual page 353

Communication controller
Table of Contents

Advertisement

Wrap Test
14
WRAP TEST UNSUCCESSFUL, SOME DATA NOT RECEIVED
is displayed on next screen
II.
• The test is not successful if:
- NBR OF WRAPS TRANSMITTED: 010
- NBR OF WRAPS RECEIVED: 008
- NBR OF WRAPS INCORRECT: 000
- Only the message 'WRAP TEST UNSUCCESSFUL, SOME DATA NOT
RECEIVED' is displayed.
Actions:
Note:
The wrap plug or the wrap cable may not be plugged on the LlC.
~
to end the function.
- Return to the problem determination procedure you come from
(Chapter 9 or 10) to perform the specific action.
If you started wrap tests without performing any other tests, for a better
problem determination, we advise you to go to:
• Chapter 9, "LlC and Line Problems (LSS)" on page 9-1.
• Chapter 10, "Line Problem (HSS)" on page 10-1.
Remove the wrap plug and reconnect the LlC cable(s), first at the 3745 end,
then at the wall socket.
Screen
II
--------------------------------------------------------------------------------- mm/dd/yy
hh: mm
FUNCTION ON SCREEN: WRAP TEST
WRAP TEST RESULTS
LINE ADDRESS: 0
LCD 9: SDLC
TYPE: CNTRL
LEVEL: MODEM .
CNTRL PGM: NCP
Lie
TYPE: 3
NBR OF WRAPS
NBR OF WRAPS
NBR OF WRAPS
TRANSMITTED:
mm
RECEIVED:"
INCORRECT: •
= = =
>
WRAP TEST UNSUCCESSFUL, SOME DATA NOT RECEIVED
F1:END F2:MENU2 F3:ALARM F4:TEST INITIALIZATION
16-10
IBM 3745 Communication Controller: Problem Determination Guide
o

Advertisement

Table of Contents
loading

Table of Contents