o
o
o
o
o
ALARM 60: LA nn (LINES xxxx-yyyy) RE-IML IN PROGRESS
hhmmss ref code
Cause:
Action:
Line adapter microcode
Control program
If the problem recurs:
CO
and give reference code.
ALARM 61: LA nn (LINES xxxx-yyyy) RE-IML COMPLETE. DUMP
hhmmss ref code
Cause:
Action:
Line adapter microcode
Control program
Line adapter
• Transfer the line adapter dump to the host and print it. Refer to the NCP, SSP, and EP
Diagnosis Guide.
• Transfer and print control program dump.
• Reactivate lines from the host and retry.
• If the problem persists:
CO
and give the reference code of the preceding alarms
related to this one. To display the alarms, use the Event Log Display (ELD) function.
Refer to the 3745 Advanced Operations Guide.
ALARM 62: LA nn (LINES xxxx-yyyy) DOWN. DUMP
hhmmss ref code
Cause:
Action:
Control program
Line adapter
MOSS microcode
• Transfer the line adapter dump to the host and print it. Refer to the NCP, SSP, and EP
Diagnosis Guide.
• Re-IML the line adapter using the IMS function. Refer to the 3745 Basic Operations
Guide, SA33-0098. If the IML is successful, re-activate the lines from the host and retry.
• If the problem recurs:
CO
and give reference code.
Chapter 1. Alarms and Alerts