IBM 3745 Problem Determination Manual page 136

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
Alerts
3745 Alert Reference Code 81,
Alert Condition The last TIC backup time out occurred and a 'not completed' level-2 interrupt has been
received. All TICs connected to this adapter are affected.
~
MOSS Console Alarm Message
~LARM
81 : TIME-OUT ERROR: TRA xx DOWN
NetView* Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Adapter Error: Local Token Ring Adapter
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X' 32AEOOBO '
SV X'92'
Alert Type
X'01'
Permanent
SV X'92'
Alert Descri ption
X'1010'
Adapter Error
SV X'92'
Probable Causes
X'3320'
Local Token-Ring Adapter
SV X'93'
X'1021'
Communication Controller Control Program
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X'3320'
Local Token Ring Adapter
SV X'96' SF X'01'
X'1021'
Communicat~on
Controller Control Program
Actions
X'13A1'
Reactivate resources attached to
SV X'96' SF X'81'
X'82'
SF
(Line Adapter Number (x'63'))
X'3300'
If problem re-occurs then do the following
X'0610'
Dump Control Program
X'0602'
Transfer and Print Control· Program Dump
X'3000'
Contact Appropriate Service 'Representative
X'32CO'
Report the following:
X'82'
SF
(Reference Code '(x'30'))
X'82'
SF
(Product Alert Reference Code (x'FO'))
X'2203'
.Review supporting data at Alert Sender
Chapter 1. Alarms and Alerts
1-119

Advertisement

Table of Contents
loading