IBM 3745 Problem Determination Manual page 23

Communication controller
Table of Contents

Advertisement

-
.-.--------.--.---
...
-----
...•
-.----.-
...
--.-------~~~
• Re-IML in diskette mode from the backup diskette.
If the problem persists:
CO
and give reference code and control panel hex code.
Notes:
1. Even if you clear this alarm successfully, record the number, time, and reference code.
(This is needed to track any transient errors on the disk).
2. If this alarm recurs,
CO
and give the particulars that you have recorded concerning
this alarm.
ALARM 07: MOSS DISKETTE ADAPTER ERROR
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView* console if the control program is not
loaded.
Cause:
Action:
Diskette adapter
Diskette drive
Diskette
Re-IML MOSS in diskette mode. If unsuccessful:
CO
and give reference code and control panel hex code .
• Re-IML in diskette mode from back-up diskette.
Notes:
1. Even if you clear this alarm successfully, record the number, time, and reference code.
(This is needed to track any transient errors on the disk).
2. If this alarm recurs,
CO'
and give the particulars that you have recorded concerning
this alarm.
ALARM 08: MOSS CONTROL PANEL ERROR
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView* console if the control program is not
loaded.
Cause:
Control panel
Internal power control unit
Action:
CO
and give reference code.
1-6
IBM 3745 Communication Controller: Problem Determination Guide
o
o

Advertisement

Table of Contents
loading