IBM 3745 Problem Determination Manual page 142

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
Alerts
3745 Alert Reference Code 87
Alert Condition: The last TIC backup time out occurred and a 'not completed' level-2 interrupt has
been received. Only this TIC is affected. No backup time out.
ALARM 87 : TIME-OUT ERROR: TIC x DOWN (TRA yy)
NetView· Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Adapter Error: Token Ring Adpt Intf
(Adapter Error: Local Token Ring Adapter Interface)
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
10
Number
X' A93454C6 '
SV X'92'
Alert Type
X'01'
Permanent
SV X'92'
Alert Description
X'1010'
Adapter Error
SV X'92'
Probable Causes
X'3220'
Token-Ring Adapter Interface
SV X'93'
X'1021'
Communication Controller Control Program
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
-
Failure Causes
X'3220'
Local Token Ring Adapter Interface
SV X'96' SF X'01'
X '1 021'
Communication Controller Control Program
Actions
X'13A1'
Reactivate resources attached to
SV X'96' SF X'81'
X'82'
SF
(Line Adapter Number (x'63'))
X'3300'
If problem re-occurs then do the following
X'0610'
Dump Control Program
X'0602'
Transfer and Print Control Program Dump
X'3000'
Contact Appropriate Service Representative
X'32DO'
Report the following:
X'82'
S"F
(Token Ring Interface Coupler Number (x'66'))
X'82'
SF
(Reference Code (x'30'))
X'82'
SF
(Product Alert Reference Code (x'FO'))
X'2203'
Review supporting data at Alert Sender
Chapter 1. Alarms and Alerts