Problems on One Line Only (L1C1 to LIC4)
CCITT V.24/V.35 Nonswitched - Modem Attachment (Continued)
In addition to the analysis of OTR and DSR statuses, the following table may help you continue problem
determination.
If on the screen, the STATUS of
Perform the following ACTIONS:
the data set lead is:
Duplex lines:
If RTS is permanently OFF:
RTS OFF and
-
Activate the line.
RFS OFF
-
If not, check the scanner and system
generation parameters.
Duplex lines:
-
Check the OTE-to-OCE cable connection.
RTS ON and
-
Check if the DCE is powered ON and correctly
RFS OFF
connected.
Half-duplex lines:
Because of synchronization between the refresh rate and the
RTS and RFS do not flash
transmission rate, data may never appear. To verify if data is being
transmitted, press F8. If no data:
-
Check if the DCE is powered ON and correctly
connected.
-
Check the OTE-to-DCE cable connection.
Half-duplex lines:
-
Check the OTE-to-DGE cable connection.
RTS ON and
-
Check if the DeE is powered ON and correctly
RFS OFF
connected or configured.
Point-to-point:
Check -data transmission. Press F8.
CD OFF
If
no data in receive buffer, suspect network problem.
Multipoint:
Check the local DCE, the link, or the remote site (network problem).
CD ON steady
TION
Reset the OCE test switch to normal operating position.
MTON
Reset test condition at the. host side.
NS
Not significant
RION
Not significant
All data set leads are OK but
Check terminal configuration at the remote site and
th~
control program
there is traffic on the transmit
generation parameters (for example, the remote terminal address,
side only.
NRZ-I, or non-NRZ-I).
9-14
IBM 3745 Communication Controller: Problem Determination Guide