IPL Problems (Channel-Attached)
Looking at the host console:
If
~
A message at the host console indicates
an unsuccessful load (load from the
host).
The control program activation fails.
Any other messages at the host
console.
Looking at the
MOSS console:
If
Following a load from the host, the
control program initialization fails with
an abend code of X'7000'.
Use the MOSS ElD function to display
the alarms and to check the abend
codes.
The abend 'code is displayed in the MSA
field of the MOSS screen but may be
displayed for a short period of time and
not being noticed.
Do
1. On the 3745, note the hex cqde on
the control panel and the alarm
(with the reference code, if any) on
the console.
2. Re-IPL the 3745. When the control
panel ,displays the hex code FF4, do
not load the control program.
3. Take a control program dump from
the host and check the control
program generation parameters.
4.
CO
with the reference code.
Check the control program node
address and the control program n'ame.
Ask the host operator to perform
appropriate action.
Do
Check the value of the NCP USGTIER
keyword which may have been wrongly
set at NCP generation time for this 3745.
See" Usage Tier Problems" on
page 2-3.
If the usage tier was correctly defined,
then
CO
8-2
IBM 3745 Communication Controller: Problem Determination Guide
o
,
o