ALARM 42: SYSGEN ERROR: xxxx RE·IPL COMPLETE CCU-x. DUMP
hhmmss ref code
Cause:
Action:
Communication controller control program
Processor
Main storage
Adapter
• Transfer the control program dump to the host and print it. Refer to the NCP, SSP, and
EP Diagnosis Guide.
• Resume operations and perform problem determination procedures. If the problem
occurs repeatedly:
Check and, if
~ecessary,
correct generation parameters. There may be a mismatch
between hardware configuration and software generation parameters.
Refer to the appropriate control program documentation (NCP or else) for the abend
code
xxxx
description.
ALARM 43: CONTROL PROGRAM REPORTED ERROR: LINE xxxx DOWN
hhmmss ref code
Cause:
Action:
LlC or line adapter hardware
Adapter
microco~e
Control program
Mismatch between hardware and software.
1. If it is
a
HPTSS line,
CO
and give reference code.
2. If it is a low or medium speed TSS, check whether the LlC or its lines have just been
installed or modified.
• If yes: Verify if the NCP and CDF are matching the LlC configuration. (For a L1CS or
a L1C6 check the configuration sheet values with a PKD.)
If no, correct them. Reload the scanner if other lines are down. Restart the
lines.
If yes, replace the L1C (refer to the 3745 Connection and Integration Guide) and if
the problem persists,
CO
• If no: verify if any other lines driven by this scanner are down.
If no, replace the L1C.
Refer to the 3745 Connection and Integration Guide.
If yes and all the down lines are on the same L1C, the.n re.pJace the L1C.
Refer to the 3745 Connection and Integration Guide.
1-18
IBM 3745 Communication Controller: Problem Determination Guide