IBM 3745 Problem Determination Manual page 159

Communication controller
Table of Contents

Advertisement

Alerts
3745 Alert Reference Code A7
Alert Condition: An airflow detector is experiencing a fault condition with a cooling fan of a 3745
power supply (line adapter, channel adapter, LlB1 or LlB2, but not MOSS). A return to normal will be
indicated by alert AD.
G
MOSS Console A.larm Message
ALARM A7 : COOLING PROBLEM
~
NetView' Alert· Dynamic
Loss of Equipment Cooling: Cooling Fan
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert
ID
Number
X ' E93DBDA9
1
SV X'92'
Alert Type
X
1
01
1
Permanent
SV X'92'
Alert Description
X ' 1501
1
Loss of Equipment Cooling
SV X'92'
Probable Causes
X ' 0301
1
Cooling Fan
SV X'93'
-
User Causes
X ' 74A1
1
Blocked Air Filter
SV X'94' SF X'01'
Actions
X ' 1310 '
Verify that Air Vents are nO.t covered
SV X'94' SF X'81'
X ' 1311
1
Check for dirty Filter
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X ' 0301
1
Cooling Fan
SV X'96' SF X'01'
X ' 0310 '
Air Flow Detector
X ' 0202
1
Internal Power Control Unit
Actions
X ' 3000 '
Contact Appropriate Service Representative
SV X'96' SF X'81'
X ' 32CO '
Report the following:
X ' 82
1
SF
(Reference Code (x'30'))
X ' 82
1
SF
(Product Alert Reference Code (x'FO'))
1-142
IBM. 374S Communication Controller: Problem Determination Guide