IBM 3745 Problem Determination Manual page 252

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
IPL Problems (MSA Fields Definition)
FALLBACK COMPLETE
+
ERRORS: The fallback is complete although an error
has been encountered. The 3745 should run normally.
FALLBACK IN PROGRESS: The fallback operation is in progress.
IPL CANCELLED: The 3745 initialization is cancelled by:
e
The operator (immediate terminate function).
Operator console power-OFF when the IPL was requested
from the console.
e
The operator console switching from normal mode to test
mode.
• Automatic MOSS re-IML during a CCU/scanner step-by-step
IPL, or
• Two automatic MOSS re-IMLs during a CCU/scanner IPL.
IPL CHECK Fxx: The IPL ends abnormally. The check code (Fxx) is also
displayed on the hex display of the control panel.
. IPL CHECK F1B CLOP ABEND xxxx: The IPL ends abnormally. xxxx is the
hexadecimal CLDP abend code.
CO
IPL COMPLETE: The IPL is successfully completed.
IPL COMPLETE
+
ERRORS: The IPL is complete, although an error has been
encountered. Alarm D1 is displayed. The 3745 runs with some
restrictions.
IPL FROM MOSS DISK IN PROGRESS: The IPL from the MOSS disk is in
progress .
. IPL IN PROGRESS: The IPL operation is in progress. The progression of the IPL
is indicated in MSA field F which displays the control program
storage addresses. Refer to the 3745 Advanced Operations
Guide for further details on MSA fields.
LINK IPL DETECTED ON L xxxx: The control program loading/dumping is started
on a link-attached 3745.
LINK TEST PROGRAM ABEND: A hardware error occurred at phase 3,
w~ile
loading the stand-alone link test.
LINK TEST PROGRAM LOADED: The link test program is loaded.
LOAD IN PROGRESS ON CA xx: The control program is being loaded on a
channel-attached 3745. The progression of the load is -indicated
in MSA field F where the CCU storage addresses are displayed.
x is the channel adapter number. Refer to the 3745 Advanced
Operations Guide for further details on MSA fields.
LOAD IN PROGRESS ON L xxxx: The control program is being loaded on a
link-attached 3745. The progression of the load is indicated in
MSA field F where the
ccLf
storage addresses are displayed.
xxxx is the decimal telecommunication line address. Reler to
the 3745 Advanced Operations Guide for further details on MSA
fields.
RPO DETECTED ON L xxxx: The remote power OFF (RPO) command is detected
on telecommunication line xxxx. xxxx is the decimal
telecommunication line address.
Chapter 8. IPL Problems (From Host or Disk)
8-17

Advertisement

Table of Contents
loading

Table of Contents