IBM 3745 Problem Determination Manual page 24

Communication controller
Table of Contents

Advertisement

o
o
o
o
o
ALARM 09: MOSS IML COMPLETE
hhmmss ref code
Note: The corresponding alert is not displayed on the NetView* console if the control program is not
loaded.
Cause:
Action:
MOSS hardware
MOSS microcode
• Perform the action required by the hex code.
• If the problem recurs:
CO
and give reference code and control panel hex code.
ALARM OA: MOSS-TO-LOCAL CONSOLE TRANSMISSION ERROR
hhmmss ref code
Cause:
Action:
Console adapter
Console cable
Console
Perform a console link test (see Chapter 17):
• If unsuccessful,
CO
and provide reference code.
• If successful, go to Chapter 6, "Local or Alternate Operator Console Problems."
ALARM 08: LOCAL CONSOLE ERROR
hhmmss ref code
Cause:
Action:
Local console
Console cable
Console adapter
Perform a console link test (see Chapter 17):
• If unsuccessful,
CO
and provide reference code.
• If successful, go to Chapter 6, "Local or Alternate Operator Console Problems."
ALARM OC: MOSS-TO-REMOTE CONSOLE TRANSMISSION ERROR
hhmmss ref code
Cause:
Action:
Console adapter
Local DeE interface cable
Communication line
Console or modem
Incorrect hardware configuration
Perform a console link test (see Chapter 17):
• If unsuccessful,
CO
and provide reference code.
• If successful, go to Chapter 7, "Remote Operator Console Problems."
-
Check if modem is powered on and operational.
Chapter 1. Alarms and Alerts
1:..7

Advertisement

Table of Contents
loading