Alerts
3745 Alert Reference Code 38
Alert Condition: The adapter microcode dump has been successfully completed before a re-IML due
to a detected microcode error (or provisionally after a CP protocol error with the adapter).
The dump file on MOSS disk needs to be transferred and printed at host, on the same way as for line
adapter/scanner at VTAM console.
ALARM 38 : MICROCODE ERROR: ELAyy DUMP TAKEN
NetView· Alert - Dynamic - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ,
Microcode pgr abnorm term: Local CSMA/CD adapter
(Microcode program abnormally terminated: Local CSMA/CD adapter)
Subvector and
Code
Causes and Actions
Subfield Keys
Points
Alert ID Number
X I C4AAAF3A I
SV X'92'
Alert Type
X I 01
1
Permanent
SV X'92'
Alert Description
X I 6000
1
Microcode program abnormally terminated
SV X'92'
Probable Causes
X I 3322
1
Local CSMA/CD adapter
SV X'93'
User Causes
(none)
SV X'94' SF X'01'
Install Causes
(none)
SV X'95' SF X'01'
Failure Causes
X I 3322
1
Local CSMA/CD adapter
SV X'96' SF X'01'
XI3331I
Adapter microcode
Actions
X I 0603
1
Transfer and print line adapter dump
SV X'96' SF X'81'
XIFOAO I
For:
X I 82
1
SF
(Adapter number (x'61'))
'yy'
XI FOAOI
For:
X I 82
1
SF
(Product alert reference code (x'FO'))
'38'
Chapter 1. Alarms and Alerts