8. FINAL COMMISSIONING CHECKLIST

Perform the following to verify installation was successful
PASS CRITERIA
Verify display shows SAM Boost™ splash screen while pump is in
road mode & transmission in drive gear (use two people for safety)
Manually operate preconnected valves from display – full open and full
close (Does not require to be in pump gear)
Manually operate tank-to-pump valve from display - full open and full
close (not required to be in pump gear)
Place truck into pump gear and verify no warnings appear
Manually increase and decrease engine RPM with the display
(If unable to do so, verify governor settings [Password: 00311])
Verify emergency idle functions from the display
(press mode button to revert to PSI Mode)
While in PSI Mode, manually increase pump set pressure to 100 PSI
(or any value that increases engine RPM.) Verify that master
discharge gauge pressure matches pump set pressure on the display
Operate nozzles to open the paired preconnect valves
With two people for safety, validate nozzle calibration is correct. Have
one person hold the nozzle with bail fully open & the other person
check the display to see that actual pressure equals rated pressure
with calibrated hose length by pressing the nozzle info button
Validate nozzle signal strength is reading appropriately. This can be
checked by pressing the nozzle info button
Validate truck voltage is reading appropriately. This can be checked
by pressing the nozzle info button
(If incorrect, adjust on 06565 password page)
Check engine oil pressure & temperature by pressing the nozzle info
button
Drain tank while in tank mode to trip low tank warning (audible &
visual). Warning should trip at ¼ tank level
(Validate buzzer operation and tank calibration)
Apply hydrant pressure, close tank-to-pump, and validate that nozzle
display changes to blue
Sheet: FSG-MNL-00234
SAM BOOST™ WITH SMART NOZZLE N
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Section
Number
Page: 59 of 66
6.2.1
6.2.6
6.2.4
6.2.1
6.1.1
6.1.1
6.1.1
6.2.3
6.1.2
6.1.2
6.1.2
6.1.2
6.3.1
6.2.2

Advertisement

Table of Contents
loading

Table of Contents