SAM BOOST™ WITH SMART NOZZLE N
It is recommended to install the water tank level transducer connector oriented between
45° to 90° from the horizontal to allow drainage and avoid sediment build-up.
□
Once all components have been installed, connect the SAM Boost™ Harness to the new water tank
level transducer per the System Layout Drawing (FSG-PL-01530).
o
Provide a service loop to the harness plugging into the tank level sensor.
□
Calibrate tank level using the Tank Level Calibration Password (08265)
6. OPERATION
The sections below detail screen functionality and general SAM Boost™ Operation
SAM BOOST™ SCREEN LAYOUT
6.1
There are 3 main operation screens in SAM Boost™ that have following functions:
1. Home Page
i. Discharge valve status
ii. Tank to pump control and status
iii. Engine Information and control.
2. Discharge Valve 1 Page
i. Discharge Valve 1 Status
ii. Discharge Valve 1 control
iii. Nozzle 1 Status
3. Discharge Valve 2 Page
i. Discharge Valve 2 Status
ii. Discharge Valve 2 control
iii. Nozzle 2 Status
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 33 of 66