SAM BOOST™ WITH SMART NOZZLE N
12. Tank to pump current position. Bar graph will slide based on valve % open.
13. Valve Friendly Name – This is a customizable name from a select list.
14. Valve Set Pressure
a. Wi-Fi Bars will change color (RED, YELLOW, & GREEN) based on nozzle signal strength.
b. Nozzle icon will change color (RED, YELLOW, & GREEN) based on battery life.
15. Valve Actual Pressure
*Note this is valve pressure and not nozzle pressure
16. Valve Status
a. Blue = Good
b. Orange = Manual
c. Black with low flow text = Low flow mode
d. Yellow = No Nozzle Control (Loss of signal or no battery life)
17. Current RPM
18. Interlock status (okay or not okay)
19. Governor mode selected. Blue is PSI MODE, orange is RPM MODE, grey if no mode is selected.
20. Change governor mode (PSI MODE or RPM MODE)
21. Oil temperature, coolant temperature, gearbox temperature and battery status.