Storing Batteries; Disposing Of Batteries; Safety; Akron Valve Maintenance - Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
9.2.3

STORING BATTERIES

When batteries will not be used and placed into long term storage such as being taken out of service for many
months, they should be stored in a cool, dry place and at 40% (3.86V) charge. The battery level can be
checked if connected to a SAM™ SMART NOZZLE and viewed from the nozzle information screen. Make
sure to fully charge batteries prior to use when removing from long term storage.
9.2.4

DISPOSING OF BATTERIES

Do not dispose of the batteries in your regular trash pickup. They must be taken to a location that can properly
recycle Lithium-ion batteries.
9.2.5

SAFETY

Using any battery other than Hale Products P/N 200-00173-000 can potentially damage your SAM™
SMART NOZZLE. Failure to do this increases the chance of fire and will void your warranty.
9.3

Akron Valve Maintenance

Please review Akron Brass document 127903 for list of valve parts.
9.3.1

Akron Valve Exercise

It is recommended to actuate the valves weekly to ensure proper performance and valve lubrication. This
applies to both discharge valves and the tank-to-pump valve. Follow the steps below:
1. Tank-to-pump exercise
a. Go to Home Page
b. Hold the + button to open valve fully
c. Hold the – button to close valve fully
2. Discharge valve exercise
a. Go to valve control page.
b. Hold the + button to open valve fully
c. Hit the close button to close valve fully.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Keep batteries in a battery safe container when not installed in a SAM™ SMART
NOZZLE.
Do not expose batteries to high temperature.
Do not charge batteries unattended.
Do not disassemble or modify battery.
Do not short circuit battery.
Do not dispose of batteries in a fire.
Action
Exercise Valve
Pressure Calibration
Clean out sensor
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Cadence
Weekly
Annually
As needed
Page: 62 of 66