Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual page 24

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
It is recommended to install the valve motor such that the electric connectors are oriented
downward or sideways to avoid water build-up and intrusion. If the valve motor has been
rotated, the position sensor will require calibration at the SAM Boost™ Display using
password 08266.
Install the pressure transducers on the outlet side of the valve into drain Line or gauge Line. Pressure
transducers are pre-installed with ¼" NPT adapters to prevent damage to the sensor from
overtightening.
Connect transducers to valves using harness 513-00145-007.
o
Provide a service loop to the harness as shown below.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28