Pump Engagement

Engaging the pump will cause the following sequence:
1. Display will switch from splash screen to home page.
2. The Tank-to-pump will automatically open
3. The system will enter PSI governor mode
4. The pump recirculation valve will open.
5. If awake, the screen of the Smart Nozzle will begin showing its status and is ready to be called.
6.2.2

Smart Nozzle Status Indicators

When the Smart Nozzle is available to be activated, it will show the tank status. The SAM™ SMART
NOZZLE LED display provides water tank level on the truck. This is done via wireless communication
between the SAM™ SMART NOZZLE and the SAM BOOST™ system. Below are the various display
status for different tank conditions. Green is a full tank (greater than 75% full), yellow is partially filled tank
(75%-25% full), and red is a low tank (Less than 25% full).
When a hydrant is established and the tank to pump valve is closed at the SAM BOOST™ truck, the SAM™
SMART NOZZLE will automatically switch to a full blue display to indicate this condition.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Tank level indication on the SAM™ SMART NOZZLE are visible only when the pump
is engaged (pump mode) and the nozzle is active.