Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual page 41

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
The Smart Nozzle can only be activated via the two function buttons when the system meets the following
conditions:
1. Governor must be in PSI mode
2. The corresponding discharge valve must be closed.
3. The corresponding discharge valve must not be in manual mode.
When ready to activate a paired SAM™ SMART NOZZLE and valve, SIMULTANEOUSLY press and hold
the two function buttons located on either side of the SAM™ SMART NOZZLE module for a minimum time of
2 seconds. Release after the 2 second period. The LED display on the SAM™ SMART NOZZLE will illuminate
in a yellow wig-wag sequence as shown below indicating the request to provide discharge water has occurred.
The wig-wag sequence will continue for approximately four (4) seconds and will then switch to indicate tank
level on the display. The associated valve will commence to open and provide water to the SAM™ SMART
NOZZLE.
Upon a successful Smart Nozzle charge:
1. The valve will open to the desired set pressure.
a) The valve will automatically adjust position to maintain set pressure.
b) The set pressure will automatically adjust to maintain nozzle pressure.
2. The master pump pressure will increase to 10 psi above valve set pressure.
3. The nozzle Icon will appear on the screen.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Do not switch SAM™ SMART NOZZLEs between discharges after the pairing
process. Doing so can result in the opening of discharges other than the discharge
connected to the paired SAM™ SMART NOZZLE which may cause bodily injury.
Charging the nozzle, may increase the engine rpm and system pressure. This may
increase pressure on all discharge lines.
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 40 of 66