SAM BOOST™ WITH SMART NOZZLE N
o
The following transducers are included:
▪
▪
▪
□
Orient all modules so that connectors are not facing up (to avoid accidental water intrusion). This
rule applies to the following modules:
o
Matrix module
o
Radio module
o
CAN Distribution modules
o
Discharge valves
o
Tank-to-pump valve
5.2
RADIO MODULE INSTALLATION
See plate drawing 546-00119-000 for radio module and antenna installation drawing.
The system includes an optional mounting bracket that can be installed to either a 2.5", 3", or 4" side discharge
valve; however, location of the radio module is dependent on the location of the antenna with its coaxial cable.
It is recommended to select the antenna mounting point first and determine if the cable length to the radio
module is feasible before final mounting of the radio module. Avoid installing the radio module near power
lines or equipment sensitive to noise. Follow the steps below to mount radio module
□
Locate desirable location of module located 8' from the antenna and 39" from a CAN distribution hub.
•
Typically mounting the antenna to the pump house or the rear cab body will not require an
extension as there is usually enough length to route back to the CAN Network Hub.
•
If required to mount the radio module beyond the provided length contact technical support
□
Mount Module to Valve
•
Adapter fits 2.5", 3", or 4" Valves
It is recommended to install the module such that the electric connectors are oriented
□
Connect harness as shown on System Layout
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Master discharge and intake transducer
Valve discharge pressure transducer
Tank Level transducer.
downward or sideways to avoid water build-up and intrusion
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28