Charging Batteries; Installing Batteries - Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
9.2.1

CHARGING BATTERIES

Lithium-ion batteries do not have a charge memory, so deep discharging is not required. It is better to use
partial discharge cycles via normal use of the SAM™ SMART NOZZLE. It is recommended, however, to log
the amount of times batteries are charged for reference. The battery level can be checked if connected to a
SAM™ SMART NOZZLE and viewed from the nozzle information screen. Additionally, the battery voltage
level can be checked on the battery charger's LED screen.
For more information on charging the batteries, please refer to Tenergy TN471U battery charger Battery
Charger Instruction Manual.
9.2.2

INSTALLING BATTERIES

Unscrew the battery cap thumbscrew by turning it counterclockwise and remove the battery cover. Remove
the depleted batteries and place in the battery charger for recharging. Insert freshly charged batteries.
Observe polarity for proper (+) and (-) placement. Before replacing the battery cover, inspect and remove
any dust or dirt on the mating surfaces of the battery cover and housing. Replace battery cap and tighten the
thumbscrew until it will not turn.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Only charge one battery per charger slot.
To prevent ignition of a hazardous atmosphere, batteries must only be changed
in an area known to be nonhazardous.
Change batteries in a clean dry area to avoid internal contamination.
Only one battery is required to power the SAM™ SMART NOZZLE. For maximum
life, install two batteries.