If the user interacts with the discharge valve on the screen or there is an issue with the nozzle then the
valve will enter Nozzle Override state as shown above. In this state, the nozzle icon will disappear and be
replaced with the desired valve set pressure. Nozzle auto control will be turned off in this state, but regular
SAM control is still available. This state can be achieved in the following ways:
Opening valve with preset button on the screen
Loss of signal with nozzle
Manually change valve set pressure with the up/down arrows on the valve control page.
Decreasing master discharge pressure.
Going into RPM mode
Hitting the idle button
6.2.6

Discharge Valve Manual Override