SAM BOOST™ WITH SMART NOZZLE N
If the user interacts with the discharge valve on the screen or there is an issue with the nozzle then the
valve will enter Nozzle Override state as shown above. In this state, the nozzle icon will disappear and be
replaced with the desired valve set pressure. Nozzle auto control will be turned off in this state, but regular
SAM control is still available. This state can be achieved in the following ways:
•
Opening valve with preset button on the screen
•
Loss of signal with nozzle
•
Manually change valve set pressure with the up/down arrows on the valve control page.
•
Decreasing master discharge pressure.
•
Going into RPM mode
•
Hitting the idle button
6.2.6
Discharge Valve Manual Override
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 43 of 66