Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual page 57

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
Follow the steps below to pair a nozzle to the system:
1. Press and hold both right and left buttons on the nozzle until the green LEDs flash alternately
forward then rearward. (sending radio signal to connect)
2. Observe the green LEDs until the forward and middle LED flash at the same rate. This indicates
the connection between the nozzle and 6037 radio module.
3. The screen will display the serial number of the nozzle being paired below both empty boxes in the
lower open area of screen.
4. Press the desired 'Pair' button in the top right corner to complete the process. The S/N will appear
in the corresponding valve box when paired. (Two nozzles paired in image below)
To unpair a nozzle, press 'Unpair' button in the upper right corner that corresponds to the desired valve line.
Repair nozzle by using steps 1 through 4 above.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 56 of 66