For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
4.5

TANK-TO-PUMP OVERVIEW

The SAM BOOST™ system provides an electric tank-to-pump valve that is controlled via the SAM BOOST™
display. This valve will automatically open on pump engagement and will automatically close on pump
disengagement
A pump venting solenoid is provided with the system that works in conjunction with the tank-to-pump valve.
When the tank-to-pump valve is open, the solenoid will activate to vent out air that may be trapped inside the
pump.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
Valve handle will automatically rotate while in SAM™ SMART NOZZLE Mode or
SAM Mode and poses an entanglement risk. Keep hands clear. Remove power from
valve before trying to manually override via the override knob.
Valve handle will automatically rotate while engaging or disengaging pump and
poses an entanglement risk. Keep hands clear. Remove power from valve before
trying to manually override via the override knob.
The pump venting solenoid does not act as a pump cooler. Please follow your
jurisdiction's SOP for pump cooling and recirculation.