SAM BOOST™ WITH SMART NOZZLE N
□
Plan mounting location of CAN network Hubs
o
It is recommended to have one located on passenger side and one on driver side of pump
house.
To maintain J1939 Standards all CAN nodes must be within 39" of a CAN Hub. Nodes
o
include:
▪
Discharge valves
▪
Tank-to-pump valve
▪
Nozzle Radio Module
o
The harness that connects hubs together has a power leg (shown below) that must be
connected to chassis power
▪
Installer should plan hub placement so that the power leg is easily accessible on
either driver side or passenger side of the truck.
o
Example CAN Hub location shown below
□
Once a viable location and orientation has been determined, torque the mounting fastener until the
assembly cannot rotate.
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 26 of 66