SAM BOOST™ WITH SMART NOZZLE N
It is recommended to install pressure transducers so that they are oriented 45 degrees
above horizontal to ensure proper drainage and avoid buildup of sediment.
It is recommended to torque sensors at the adapter fitting as overtightening the sensor
itself can alter factory calibration. If recalibration is required, follow the instructions in
the password section for pressure calibration (08266).
Connect the SAM Boost™ Harness to transducers per the system layout drawing (FSG-PL-01530).
o
Provide a service loop at the transducers.
5.9

WATER TANK COMPONENT INSTALLATION

The SAM Boost™™System includes two assemblies that will require installation into the truck water tank, the
Pump Venting Solenoid and SAM Boost™ Tank Assembly.
5.9.1

PUMP VENTING SOLENOID INSTALLATION

The Pump Venting Solenoid installation is divided into two assemblies, the solenoid and check valve
assembly.
The solenoid assembly will need to be installed on the discharge side of the pump. Follow the steps below:
Locate a suitable ¼" NPT port
Install the assembly with pencil strainer side inserted into the pump
Connect the solenoid to the main harness and provide strain relief.
The check valve assembly will need to be installed either on the truck water tank or on the discharge side of
the Tank Fill valve (shown below).
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
PHONE: (800) 288.1161
www.akronbrass.com
Revision 2023-08-28
P AND UV780 DISPLAY
2
Page: 31 of 66