Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

Quick Links

OPERATION INSTALLATION MAINTENANCE
MANUAL
FOR SAM BOOST™ WITH
SMART NOZZLE N
P AND UV780 DISPLAY
2
BY
Akron Brass, INC.
A Unit of IDEX Corporation
1615 Old Mansfield Road, Wooster, OH 44691
(800) 288.1161
www.akronbrass.com
MANUAL P/N: FSG–MNL–00234
COPYRIGHT © 2022 – 2023 BY HALE PRODUCTS, INC. ALL RIGHTS RESERVED

Advertisement

Table of Contents
loading

Summary of Contents for Idex Akron Bras SAM BOOST

  • Page 1 MANUAL FOR SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY Akron Brass, INC. A Unit of IDEX Corporation 1615 Old Mansfield Road, Wooster, OH 44691 (800) 288.1161 www.akronbrass.com MANUAL P/N: FSG–MNL–00234 COPYRIGHT © 2022 – 2023 BY HALE PRODUCTS, INC. ALL RIGHTS RESERVED...
  • Page 2: Table Of Contents

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Contents SAFETY ..............................3 GENERAL INSTRUCTIONS ........................3 WHAT’S INCLUDED ..........................4 Box #1 – SAM Boost™ Electronic Components ....................7 Box #2 – SAM Boost™ Valves & Venting Components..................7 SAM BOOST™...
  • Page 3 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.1.2 Discharge Valve Page ........................ 37 SAM BOOST™ Standard Operation ......................38 6.2.1 Pump Engagement ........................38 6.2.2 Smart Nozzle Status Indicators ....................38 6.2.2.1 Smart Nozzle Error Status ....................
  • Page 4: Safety

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 9.3.1 Akron Valve Exercise ........................62 9.3.2 Akron Valve Pressure Calibration ....................63 Pump Vent Solenoid Maintenance ......................... 63 Master Pressure Transducer Maintenance ..................... 64 Tank Level Sensor Maintenance ........................
  • Page 5: What's Included

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 3. WHAT’S INCLUDED For full system layout reference Hale Drawing FSG-PL-01530. SAM Boost™ System comes delivered in two boxes. Summary of included items are as follows: PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234...
  • Page 6 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Box #1 – SAM Boost™ Electronic Components PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234 Revision 2023-08-28 Page: 5 of 66...
  • Page 7 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Box #2 – SAM Boost™ Valves & Venting Components PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234 Revision 2023-08-28 Page: 6 of 66...
  • Page 8: Box #1 - Sam Boost™ Electronic Components

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Box #1 – SAM Boost™ Electronic Components A. Batteries & Battery Chargers • Four batteries per nozzle-Tenergy 750 mAh Li-ion rechargeable type B. Wireless CAN Module & Antenna C.
  • Page 9: Sam Boost™ Example Build

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL SAM BOOST™ Example Build PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234 Revision 2023-08-28 Page: 8 of 66...
  • Page 10: Assembly Diagram

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Assembly Diagram *Items in dotted line boxes may vary per customer order PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234 Revision 2023-08-28 Page: 9 of 66...
  • Page 11: Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 4. OVERVIEW Firefighting is an inherently risky activity. Understand operation and limitations of equipment and check for flow before entering any Immediately Dangerous to Life and Health (IDLH) environment.
  • Page 12 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL The SAM™ SMART NOZZLE is paired to a single discharge valve. Do not place the nozzle on a different discharge valve. Doing so can result in the wrong discharge valve opening, which may cause bodily injury.
  • Page 13: Batteries And Charger Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL BATTERIES AND CHARGER OVERVIEW The SAM™ SMART NOZZLE comes with Lithium-ion rechargeable batteries. These batteries must be fully charged prior to first use and will last approximately 8 hours during pumping operations. Use only the battery charger supplied.
  • Page 14: Discharge Valve Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Typical display shown The SAM BOOST™ system comes with a display that will replace an existing governor on a truck. The SAM BOOST™ display allows for the following: •...
  • Page 15: Tank-To-Pump Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Valve handle will automatically rotate while in SAM™ SMART NOZZLE Mode or SAM Mode and poses an entanglement risk. Keep hands clear. Remove power from valve before trying to manually override via the override knob.
  • Page 16: Nozzle Radio Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL NOZZLE RADIO OVERVIEW The SAM BOOST™ system provides a SAM™ SMART NOZZLE radio module and antenna. This module allows the display and the nozzles communicate with each other. Maximum communication range is 300 ft. The nozzle and display will show radio communication status and indicate any issues.
  • Page 17: Can Distribution Module And Wiring Harness Overview

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Master discharge/intake pressure transducers arrive from the factory calibrated. Only use pressure transducers that have been provided. The tank level transducer is not calibrated. User must calibrate tank level. The matrix governor can operate the engine in either RPM or PSI control modes.
  • Page 18: Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL The SAM BOOST™ system also includes a set of harnesses that connect nodes to the distribution modules. 5. INSTALLATION ™ A successful SAM BOOST application starts with identifying the engine control type so to ensure compatibility.
  • Page 19: Harness Installation Best Practices

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Installation scope of work: □ Remove original discharge valves and controls □ Remove original tank-to-pump and controls □ Remove original governor display (leave harness intact) □...
  • Page 20: Radio Module Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL The following transducers are included: ▪ Master discharge and intake transducer ▪ Valve discharge pressure transducer ▪ Tank Level transducer. □ Orient all modules so that connectors are not facing up (to avoid accidental water intrusion). This rule applies to the following modules: Matrix module Radio module...
  • Page 21: Antenna Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL ANTENNA INSTALLATION See plate drawing 546-00119-000 for radio module and antenna installation drawing. The antenna provided with the system includes an 8’ length coaxial cable that connects to the radio module. This cable cannot be extended so plan a proper installation location.
  • Page 22 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL • See the drawing below for the overall antenna size and mounting hole dimensions □ Route the antenna wire • The coaxial cable cannot be shortened or lengthened with extensions. •...
  • Page 23: Discharge Valve Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL □ Protection should be provided in front of the antenna whip to prevent damage from trees or overhead objects when the truck is in transit. Refer to a certified RF Technician for installation recommendations when locating the antenna on the truck body.
  • Page 24 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install the valve motor such that the electric connectors are oriented downward or sideways to avoid water build-up and intrusion. If the valve motor has been rotated, the position sensor will require calibration at the SAM Boost™...
  • Page 25: Tank-To-Pump Valve Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install pressure transducer connectors oriented between 45° to 90° from horizontal to allow drainage and avoid sediment build-up. TANK-TO-PUMP VALVE INSTALLATION The SAM Boost™...
  • Page 26: Can Network Hub Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install valve motors such that the electric connectors are oriented downward or sideways to avoid water build-up and intrusion. If a valve motor has been rotated, the position sensor will require calibration at the SAM Boost™...
  • Page 27 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL □ Plan mounting location of CAN network Hubs It is recommended to have one located on passenger side and one on driver side of pump house.
  • Page 28: Panel Components Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install CAN Network Hubs such that electric connectors are oriented downward or sideways to avoid water build-up and intrusion. □ After CAN Network Hubs have been installed, connect each node harness to the CAN Network Hub nearest to the components.
  • Page 29: Warning Label & Cover Placard Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL □ Unplug and remove original equipment pressure governor • Leave governor harness installed as it will connect to SAM Boost™ harness □ Mount SAM Boost™ display with adapter plate □...
  • Page 30: Matrix Module Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Included in the SAM Boost™ Kit are placards for covering push-pull control cutouts. Place the placard over the exposed cutouts left after removing control components for the two preconnected discharges and Tank- to-Pump valves.
  • Page 31: Pressure Transducer Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install the module such that electric connectors are oriented downward or sideways to avoid water build-up and intrusion. 5.8.1 Pressure Transducer Installation Included with the kit are calibrated Master Intake and Master Discharge pressure transducers.
  • Page 32: Water Tank Component Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install pressure transducers so that they are oriented 45 degrees above horizontal to ensure proper drainage and avoid buildup of sediment. It is recommended to torque sensors at the adapter fitting as overtightening the sensor itself can alter factory calibration.
  • Page 33: Sam Boost™ Tank Assembly Installation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL □ Locate a suitable location for pump vent to discharge into. □ Install the check valve with the arrow pointed in the direction of flow from the solenoid. □...
  • Page 34: Operation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL It is recommended to install the water tank level transducer connector oriented between 45° to 90° from the horizontal to allow drainage and avoid sediment build-up. □...
  • Page 35: Home Page

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.1.1 Home Page 1. Go to Valve 1 Control Page a) Note: Color is customizable 2. Nozzle 1 Info button—Hold to see: a. Nozzle 1 Pressure b.
  • Page 36 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL • Oil Pressure • Engine Temp 3. Go to Valve 2 Control Page a) Note that Color is customizable 4. Nozzle 2 Info button—Hold to see: a.
  • Page 37 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 12. Tank to pump current position. Bar graph will slide based on valve % open. 13. Valve Friendly Name – This is a customizable name from a select list. 14.
  • Page 38: Discharge Valve Page

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.1.2 Discharge Valve Page 22. Discharge 1 valve control page a. Hold for Discharge 1 Manual Mode Switch 23. Nozzle info button—Hold to see: a. Nozzle Pressure b.
  • Page 39: Sam Boost™ Standard Operation

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL SAM BOOST™ Standard Operation 6.2.1 Pump Engagement Engaging the pump will cause the following sequence: 1. Display will switch from splash screen to home page. 2.
  • Page 40: Smart Nozzle Error Status

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.2.2.1 Smart Nozzle Error Status The SAM™ SMART NOZZLE uses a wireless communication method to remain in contact with the SAM BOOST™™system on the truck. If for any reason that communication is lost while in pump mode, the LED display on the SAM™...
  • Page 41 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Do not switch SAM™ SMART NOZZLEs between discharges after the pairing process. Doing so can result in the opening of discharges other than the discharge connected to the paired SAM™...
  • Page 42: Hydrant/Draft Changeover

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.2.4 Hydrant/Draft Changeover PHONE: (800) 288.1161 www.akronbrass.com Sheet: FSG-MNL-00234 Revision 2023-08-28 Page: 41 of 66...
  • Page 43: Sam Smart Nozzle Override

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Follow your jurisdiction’s SOP for hydrant or draft changeover 1. Put pump into desired Governor mode a. Some SOPs require the need to switch to RPM mode during changeover events. While in RPM mode, the Smart Nozzle will lose control since the system is governed by RPM instead of pressure.
  • Page 44: Discharge Valve Manual Override

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL If the user interacts with the discharge valve on the screen or there is an issue with the nozzle then the valve will enter Nozzle Override state as shown above. In this state, the nozzle icon will disappear and be replaced with the desired valve set pressure.
  • Page 45: System Shut Down

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL If the user holds the manual mode button on the valve control page, then the valve will enter manual override mode. In this state, there is no automatic pressure regulation. The valve will stay stationary at the position it is in until changed by the operator.
  • Page 46: System Operational Warnings

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL System Operational Warnings STANDARD DECISION There are two types of warnings on the SAM Boost™ System. Standard warnings and decision warnings. Standard warnings alert the user of an issue. Decision warnings require the user to select yes or no to a prompt.
  • Page 47: Decision Warnings

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Possible Cavitation RPM increasing but pressure is staying constant Max Valve Pressure Desired pressure at maximum value for the valve Closing Valve Valve is in process of closing Low Voltage Voltage under NFPA minimum Check Engine...
  • Page 48: Low Nozzle Pressure Warning

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 6.3.2.1 LOW NOZZLE PRESSURE Warning Do not continue increasing pressure until confirming there are no issues with the hose. Ignoring to do so will result in damage to the hose and surrounding structure of the truck and may cause bodily injury due to rapid hose expansion and movement.
  • Page 49: Checking Battery Charge Level & Wi-Fi Strength

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL CHECKING BATTERY CHARGE LEVEL & WI-FI STRENGTH The SAM™ SMART NOZZLE information can only be displayed when the nozzle is awake. Press any of the two function buttons located on either side of the SAM™ SMART NOZZLE module until the LED display illuminates to wake up the nozzle.
  • Page 50: Passwords And Calibrations

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 3. Pressing the info icon will open a new window, displaying the current battery life & Wi-Fi signal strength of each paired nozzle. a. Wake up nozzle if nozzle is not awake b.
  • Page 51 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Without the pump engaged, the operator can program valve presets, nozzle calibrations, line colors, line identifications, and other settings using passwords listed in the password table provided above. Enter a password by increasing or decreasing the number in the highlighted box with the + and –...
  • Page 52: Governor Settings (Password 00311)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Governor settings (Password 00311) This settings page (00311) will give options to set up parameters listed below. Name Current Value New Value unit of measure U.S.
  • Page 53: Sam Smart Nozzle Settings (00401)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL SAM Smart Nozzle Settings (00401) Smart Nozzle settings page gives settings for line ID, line colors, nozzle pressure presets and valve prefixes. Use the up and down arrows to select the category and the right arrow to change the values.
  • Page 54: Water Calibration Page (Password 08265)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Water Calibration Page (Password 08265) Follow the steps below to calibrate the water tank level: Fill the tank. Set the upper level using the button above the tank fill icon (635 in picture above).
  • Page 55: Valve Pressure Calibration Page (Password 08265)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 1. The valve position calibration page will automatically run ALL the valves through a position calibration when hitting the top right start button. 2. When “PASS” appears, this indicates a successful calibration. If position calibration failure, verify truck has proper voltage.
  • Page 56: Sam Smart Nozzle Pairing (Password 10600)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 1. Prior to entering password cap and then open discharge valves to be calibrated. 2. Enter password 08267 to access valve calibration screen (shown above). 3.
  • Page 57 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL Follow the steps below to pair a nozzle to the system: 1. Press and hold both right and left buttons on the nozzle until the green LEDs flash alternately forward then rearward.
  • Page 58: Sam Smart Nozzle Flow Calibration (Password 10610)

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL SAM Smart Nozzle Flow Calibration (Password 10610) Nozzle Calibration process will open the discharge valve associated with the nozzle and automatically increase line pressure. Calibration must be performed with two people 1.
  • Page 59 SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 4. Press START on the top left or right to calibrate nozzle 1 or 2 5. Valve will open and line pressure will automatically increase until nozzle meets desired pressure 6.
  • Page 60: Final Commissioning Checklist

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 8. FINAL COMMISSIONING CHECKLIST Perform the following to verify installation was successful Section PASS CRITERIA Number Verify display shows SAM Boost™ splash screen while pump is in 6.2.1 □...
  • Page 61: Maintenance

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 9. MAINTENANCE Device Action Cadence Batteries Charge Batteries After Every Use or monthly if not used Batteries Check Battery Life Weekly Valve Exercise Valve Weekly Valve Pressure Calibration Annually...
  • Page 62: Charging Batteries

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 9.2.1 CHARGING BATTERIES Lithium-ion batteries do not have a charge memory, so deep discharging is not required. It is better to use partial discharge cycles via normal use of the SAM™ SMART NOZZLE. It is recommended, however, to log the amount of times batteries are charged for reference.
  • Page 63: Storing Batteries

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 9.2.3 STORING BATTERIES When batteries will not be used and placed into long term storage such as being taken out of service for many months, they should be stored in a cool, dry place and at 40% (3.86V) charge. The battery level can be checked if connected to a SAM™...
  • Page 64: Akron Valve Pressure Calibration

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 9.3.2 Akron Valve Pressure Calibration It is recommended to calibrate the pressure transducers annually. Please follow the steps in the “Pressure Calibration Password” Section of this manual to calibrate sensors. If the sensor is ever not performing appropriately, then remove sensor, inspect sensor and line for debris.
  • Page 65: Master Pressure Transducer Maintenance

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 4. Clean or replace if clogged. Master Pressure Transducer Maintenance Action Cadence Calibrate sensor Annually Clean out sensor As Needed It is recommended to calibrate the master discharge and intake pressure transducers annually. Please follow procedure steps in the “Pressure Calibration Password”...
  • Page 66: Replacement Parts

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL 10. REPLACEMENT PARTS See drawing FSG-PL-01530 for list of replacement parts 11. MANUFACTUER INFORMATION & WARRANTY This section provides a list that includes name, address, and telephone number of the manufacturer’s points of contact.
  • Page 67: Fcc Notices

    SAM BOOST™ WITH SMART NOZZLE N P AND UV780 DISPLAY INSTALLATION, OPERATING, & MAINTENANCE MANUAL FCC ID: 2AC7Z-ESPWROOM02D 21098-ESPWROOM02D IC ID: Protocol 802.11 b/g/n Operational range: 10 feet (3.048 m) • Environmental Conditions: Operating Temperature: -20 °C (-4 °F) to 60 °C (140 °F).

Table of Contents