Smart Nozzle Error Status; Charging The Hose From The Sam™ Smart Nozzle - Idex Akron Bras SAM BOOST Operation Installation Maintenance Manual

For sam boost with smart nozzle n2p and uv780 display
Table of Contents

Advertisement

SAM BOOST™ WITH SMART NOZZLE N
6.2.2.1

Smart Nozzle Error Status

The SAM™ SMART NOZZLE uses a wireless communication method to remain in contact with the SAM
BOOST™™system on the truck. If for any reason that communication is lost while in pump mode, the LED
display on the SAM™ SMART NOZZLE is designed to turn off (go dark) as shown above. This does not
affect manual operation of the nozzle, which will still function as a normal handline nozzle without a SAM™
SMART NOZZLE system. The Boost™ system on the truck is designed to account for this situation and will
adjust as needed to maintain water flow and nozzle pressure.
If the SAM™ SMART NOZZLE is able to remain in contact with the SAM Boost™ system on the truck, but
an issue occurs at the truck before attempting to charge the hose, the LED display on the SAM™ SMART
NOZZLE will instead slowly blink red at the lower LED pair as shown above for 1 second at a 4 second
interval. Any attempts to charge the line will not occur until the issue is resolved.
Note that this error state will occur if:
System is not in PSI mode
Operator has manually overridden system
CHARGING THE HOSE FROM THE SAM™ SMART NOZZLE
6.2.3
Sheet: FSG-MNL-00234
INSTALLATION, OPERATING, & MAINTENANCE MANUAL
A paired valve with the SAM™ SMART NOZZLE can only be activated in PSI mode.
Do not activate a paired valve while hose is still packed in the hose bed, cross-lay or
speed-lay. Doing so may result in damage to the hose and surrounding structure of
the truck and may cause bodily injury due to rapid hose expansion and movement