LPG TANK AND RELATED PARTS
40
Outflow Valve
This valve controls the flow of LPG fuel from
the LPG tank to the regulator.
To open the valve .... turn it counterclockwise.
To shut the valve .................. turn it clockwise.
Inflow Valve
LPG is filled in the tank through this valve. The
tank must be filled by an LPG filling station at-
tendant. Be sure that this valve is shut tightly at
all times during use.
Pipe Valve
When the fuel hose needs to be disconnected
for tank replacement, etc., close this valve to
prevent the liquid from running out of the hose.
This valve is normally left open.
To open the valve .... turn it counterclockwise.
To shut the valve .................. turn it clockwise.
Relief valve
OPERATING LPG-POWERED FORKLIFTS
LPG outflow valve
OPEN
Pipe valve
OPEN
Relief Valve (Australian market type)
This valve prevents explosion that might be
caused when the LPG pressure rises above a
normal level or when the hose becomes deterio-
rated.
Starting the Engine (LPG Models)
1. Turn the outflow valve of the tank
counterclockwise to open it.
2. Be sure that the pipe valve is open.