Toyota 7FG35 Operator's Manual page 28

Table of Contents

Advertisement

Available languages

Available languages

w e
q Toe board
w Position "2F" with torque converter at the
2nd speed
e Position "1F" with the torque converter at
the 1st speed
Battery electrolyte check
1. The battery electrolyte should be between the
upper and lower levels (10 to 15 mm from the
top of the plates).
2. If the electrolyte level is below the lower
level, remove the cap and add distilled water to
the upper level through the water inlet port.
Caution
Be sure to use distilled water for battery elec-
trolyte. Also, wear protective glasses when
working on the battery.
Torque converter oil inspection
1. Perform oil check while the vehicle is on level
ground with the control lever in the neutral po-
sition and the engine idling.
Caution
Inspect with the parking brake lever is pulled
and the forks are lowered to the ground.
2. Open the engine hood and remove the toe-
board.
3. Extract the level gauge and wipe it with clean
cloth.
4. Insert the level gauge back to the hole from
which it is removed, and extract it again to check
if the oil level is between the F and L lines on
the level gauge.
Note: Check oil against COLD when it is not
warm (if desire so before start operating the ve-
hicle); check oil against HOT when it remains
warm (if desire so after start operating).
5. If the level is near or below the L line, add
oil to the F line.
(+) q
(-)
a
(+)
w
b, c, r
(-)
d
e
e
a. Dead-battery vehicle
b. Engine hanger
c. To frame
d. Booster cable
e. Rescue battery
Retightening of bolts and nuts
Retighten each bolt and nut on the chassis and
load handling system.
Greasing mast and steering linkage
Grease in accordance with the lubrication table.
Caution
• Clean the grease fitting tips thoroughly
prior to greasing.
• After greasing, wipe off excess grease.
When the battery is dead
When a booster cable is available, it is possible
to start the engine using the battery of another
vehicle.
1. Connect the booster cable following the se-
quence of the illustration.
Make sure of (+) and (-) terminals of the cable
when connecting.
Caution
• Connection 1: The (+) terminal of dead
battery.
• Connection 4: Use a frame apart from the
battery.
• Do not directly connect batteries to avoid a
danger of explosion. (An inflammable gas
generated from batteries may catch fire.)
27
En
En

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7fg407fg457fd357fd407fd457fgk40 ... Show all

Table of Contents