Press UP or DN to move navigation mark to ELEV(take RP P e Swito h
Elevator for example), Press R or L to shift the status between
nomal and reverse. These are two status for option. And the
default setting is Normal. All Channels Reverse Switch like:
Aileron, Throttle, Rudder, Gear, Pitch and Aux2 can be
referred to the way of ELEV Reverse Switch. And press EXT Aileron
to exit after finishing setting.
3.2 Travel Adjust
Press ENT to enter into Main Menu. Press UP or DN to move navigation mark to select item Function Menu.
Press ENT to enter Function Menu. Press UP or DN to select Travel Ajust, Press ENT to enter Travel Adjust
interface, as below illustration. It shows the Travel Adjust status of one channel:
Travel Adjust
Elevator
Take ELEV for example, Press UP or DN to move navi gation
to desired item Elevation of U. Press R or L to increase or
decrease the servo travel range. The adjustment range is
from 0.0% to 150.0%. The factory default is 100.0%.
D uu,
Press UP or DN to move navigation mark to desired item D of ELEV. Press R or L to increase or decrease
the servo travel range. The range is from 0.0% to 150.0%. The factory default is 100.0%.
All other channel's Travel Adjust like Aileron, Throttle, Rudder, Gear, Pitch and Aux2 can be referred to ELEV
travel Ajust. Press EXT to exit after setting finished.
3.3 Sub Trim
NOTE: Sub Trim is used to fine tune the servo neutral position during setup. In order to avoid pushing the
servo beyond it's limits and possibly causing damage it is advised to first mechanically adjust the servo arm/bell
crank to be as close to the neutral point as possible. Only when this is complete may sub trim be used to
make a final a djustment.
Setting method:
Press ENT to enter Main Menu, Press UP or DN to move
the navigation mark to desired item Function Menu. Press
ENT to enter Function Menu, Press UP or DN to select
Sub trim, and press ENT to enter Sub Trim interface.
The interface show the items and the channels which are adjustable. Press R or L to change the neutral point
of Servos. The default for every channel is 0.0%. The permitted adjustment ranges are show in the table below:
Adjustment range
Channel name
Adjustment range
Elevator
D62.5%--U62.5%
Gear
-62.5%—+62.5%
Aileron
R62.5% —L62.5%
Pitch
L62.5% — H62.5%
Throttle
L62.5% —H62.5%
AUX2
-62.5% —+62.5%
Rudder
R62.5%—L62.5%
Press EXT to exit after adjustment finished.
3.4 Dual rate and Exponential
Dual Rate/Exponential is a function which permits a change in behavior of the control sticks between pre-
defined settings. Dual Rate alters the maximum and minimum servo travel available, Expo has no effect on
the maximum or minimum travel but decreases or increases the sensitivity to stick movement in an exponential
manner. One use of Dual Rate/Expo is to reduce the sensitivity of the controls when landing.
Elevator
Sub Trim
Elev;=1.to:
Aileron
DEVO 7E-25