devention DEVO 7E User Manual page 69

7-channel micro computer system
Table of Contents

Advertisement

Elevator
Ail P ron
ThrottiR
Rudd Pr
Aileron
Throftli9
Rudder
F'r i I 9 ram tvl ix 1
Exponentia.1
!El
Off
Point
i
t
Point - L
L 1 21113 H
Pro 9 rain NAix 1
Status
Active
ID Li t P ut
i1
0
I
i
L I2Fi1g4H
II
cle(Lnlion
DEVO 7E
Welcome to use the DEVO 7E transmitter
(2.1) Master Channel Setup
Press UP or DN to move the navigation mark to "Master Channel"item, and press ENT to enter the Master
Channel setting interface. Press UP or DN to choose the desired channel, then press ENT to confirm the
mark ".4" before choosed channel name, press ENT to return the Program Mix 1 interface.
(2.2) Slave Channel Setup
Press UP or DN to move the navigation mark to "Slave Channel "item, and press ENT to enter the Slave
Channel setting interface. Press UP or DN to choose the desired channel, and press ENT to confirm the mark
"4"
before the Slave Channel, and "EXT" to retum Program Mix 1 interface.
(2.1) Master Channel Setup
(2.3) Position
There have two options:Pos 0 and Pos 1.Press
"UP" or "DN"to select the desired position.
(2.4) Exponential
Press"UP"or "DN"to enter "Exponential", and Press"R"
or "L" to expand a dropdown menu with two options of
Off and On. The pitch curve will be smoothly changed
L 121113 4 H
if choosing On. Otherwise choosing Off.
(2.5) Point Setup
Press UP or DN to move the navigation mark of Point option. Press R or L, there are 7 piont options including
Point-L, Point-1, Point-2 Point-M, Point-3, Point -4 and Point-H. Select the point you want to set.
(2.6) Status Setup
(There is no Status options when the piont is Point-L or Point-H). After selecting the point that you want to
set, press UP or DN to move the navigational mark to Status item. Press R or L, there are two options of
Inhibit and Active. Select Inhibit for unchanging the current amount (the default setting is Inhibit).
(2.2) Slave Channel Setup
Program Mix 1
IIII
Slave
Elevator
Position
Pos 0
(2.3) Position
(2.5) Point Setup
(2.6) Status Setup
(2.7) Output
When the Status option is Active, the Output option will be listed.Press UP or DN to move the navigational
mark to Output. Press R or L to increase or decrease, respectively, the output amount. It is possible to reverse
the mix direction by changing the plus or minus sign before the amount. The adjustable range is ±100%.
(2.8) Throttle Stick Setup
Press "UP" or "DN" to select "throttle stick setting". Press
"R"or "L" to change the data for setting its position amunt
or Inhibit. The default setting is Inhibit. The adjustable
range is 0.0-100.0%.
`F'ro gram Mix 1
Throttle Stick.
o
13
E
f
L 121113 4 H
Inhibit
Siyiyiitch
p 0
II
DEVO 7E -
66

Advertisement

Table of Contents
loading

Table of Contents