devention DEVO 7E User Manual page 57

7-channel micro computer system
Table of Contents

Advertisement

Du s.I
Rate and
E. x... 1E1
Position
Pos 0
Dual Rate
100%
Dual
Rate and Ex...
IE.
C1 1..i al Rate
r
r
11
Exporientia.1
Line
Dual
Rate and Ex..,
Flight Mode 0 !-
Pas 0
Flight Mode
Pos 0
Throttle Hold
Hold Status
c
clAntion
DEVO 7E
Welcome to use the DEVO 7E transmitter
(2) Position selection
Press UP or DN to move navigation mark to desired item Position. In the
manual mode, the function of Dual rate and Exponential will be executed
by the corresponding FMOD switch among PosO and Pos1. Take the item
Elevator at channel as an example, It's possible to shift between PosO and
Pos 1 via pushing or pulling the FMOD switch.
(3) Dual rate adjustment
Press UP or DN to move the navigation mark to desired
item Dual Rate. It's possible to change the dural rate value
of Postion via pressing R or L and the corresponding value
curve in the right top of interface will be changed accordingly.
The factory default is 100%.
(4) Exponential
Press UP or DN to select Exponential item of navigation mark. It's possible to change Dual Rate and Exponential
value in Pos when pressing R or L to change the value. There are ± 100% and Line three adjustment. At the
same time, the corresponding curve will be changed and shown at the right graph.
(5) Flight Mode 0
Press DN to move the navigation mark to Flight Mode 0, press R or L to choose PosO and Pos1.
(4) Exponential
(5) Flight Mode 0
(6) Flight Mode 1:Refer to "(5) Flight Mode 0"
Press EXT to exit after finishing the setting.
3.5 Throttle Hold
If the throttle hold function is activated in the function settings menu, it can be operated by the Throttle Hold
switch as shown in the picture below. The permitted setting range is from -20.0% to 50.0%. The default setting
is inhibited.
Press ENT to enter main menu, Press UP or DN to move navigation mark to select Function menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Hold, Press ENT to enter Throttle Hold
interface, as below illustration:
Th roldle Hold
Hold Status
111111E
Hold Position
5.0%
11
Press R or L to activate Throttle Hold function, and expansion list will be shown as Throttle hold status, throttle
hold position and Throttle hold switch.
(1) There are two items under Throttle Hold Status: Active and Inhibit. The factory default setting is Inhibit.
(2) Throttle Hold position
In the Throttle Hold interface, press UP or DN to make the Navigation mark choose "Throttle Hold Position"
setting options. Press R or L to change data, the minimum value is -20.0%; the maximum value is +50.0%.
DEVO 7E-54