devention DEVO 7E User Manual page 70

7-channel micro computer system
Table of Contents

Advertisement

a
r
P ro g ['aro
i 1
Th rottl e
c
Inhibit
S wrtc h
P
os _
L 12f113 4 H
:1;
t c: h
And
(15)Fli g ht N,, ode u
1:751 Flight
o d
e
Fl ap r'11lrrlla.l
IDA
Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E
(2.9) Switch Selection
Press UP or DN to make navigation mark select "switch" setting, prss ENT enter into useable switch interface,
press UP or DN to make navigation mark select desired switch setting.Press ENT to confirm,make left sign
from "0" to "1". If two or more items are selectable,the item And should be selected,to make left sign from "0"
to "1", Press EXT to exit after finished.
Press "EXT" to return to the interface of Program Mix for other setting. Or Press "EXT" once again to exit.
3.17 Monitor
The monitor function allows the pilot to monitor the outputs of each transmitter channel.
Press ENT to Main Menu, and use UP or DN to select Function
Monitor
Menu.Press ENT to enter the Function Menu and then use
UP or DN to select Monitor and press ENT to enter the monitor
interface for checking the current working status of each
channel(See rightside View). Press EXT to exit .
I I •
I I .
I
I
I
I
'
I
I
3.18 Fail safe
Two options exist if the receiver loses the connection with the transmitter; the first is HOLD - keep the last
action data received, the second is to use a pre-set failsafe value. The default setting is Servo Hold.
Setup:
Fai I Safe
Press ENT to Main Menu, use UP or DN to select Function
Menu. Press ENT to Function Menu then use UP or DN to
Elev
select Fail Safe and press ENT to enter the Fail Safe
interface.Take the item Elevator as an example to explain.
Use UP or DN to select Elevator on the Fail Safe interface,
SPryo H n Id
alo r
then press R or L to change the status of Servo Hold into
Fail Safe(If you want to keep Servo hold status, there is no need to re-set). There is a expanded sub-item
below. Press UP or DN to select 0%, then press R or L to increase or decrease the value, respectively, the
position amount which centers on the neutral point of servo. The available value is 125%,respectively. 0% is
the neutral point of servo.
Fail Safe
E I e', , at o r
Fail Safe
The setting methods for other channels are same as above.
Press EXT to exit after finished.
NOTE: If the helicopter enters a failsafe mode for any
reason power should be disconnected from the Heli and
it must be thoroughly checked over before flying again.
Using 100% throttle after a failsafe event may be dangerous
and cause injury or damage.
3.19 Sensor View
The function can be performed by Activate the Sensor Status in the Model Menu, and it is a must that the
receiver also has telemetry function.
Sensor View Setup: Press ENT to enter the Main Menu and use UP or DN to select the Function Menu. Press
ENT to Function Menu. Use UP or DN to select Sensor View, then press ENT to enter the Sensor View
interface. See below views. If all the sensors disconnect, there will be inhibits shown on the view, means the
telemetry signal lost. If all work normal, all the measured data will be shown.
DEVO 7E-67

Advertisement

Table of Contents
loading