(2) Volta ge Setup
There are 3 different types of voltage can be measured.It includes Internal 5V,External V1 and V2 which can
be monitored two different external voltage(i.e. battery) respectively. Once the measured voltage is lower
than the setting value, the Radio will alarm.
(2.1) Receiver 5V(Internal) PFV(Power Feeding Voltage) Alarmed value can be setted as 3.6-6V
Voltage Setup: press R or L to activate the 5V, the alarm interface will appear in the interface, please refer
to the Illustration.
VO
'tag P
IItS,!3
13
aq
Internal: 5
Internal: 5%. ,
71
1111111
6
Press UP or DN to select the Alarm Voltage setting, press R or L to set the value. The range is 3.6-6V. you
can continue to set other items after you finished.
(2.2) External V1
Press UP or DN enter to External V1 setting interface. Press R or L to activate the V1, the details refers to
the Illustration.
Press UP or DN to select the Alarm Voltage setting. Press R or L to set the value. The setting range is
0.2-99.9V. you can continue to set other items after you finished.
(2.3) External: V2 setting can refer to External V1 setting.
Press EXT back to sensor setting interface after you finished.
(3) Temperature sensor
The temperature sensor can measure up to 4 different temperature(i.e.motors). You can choose Celsius or
Fahrenheit. The alarmed value can be setted to 4 different temperature. Once the measured value is higher
than the setting value, the radio will alarm. The Alarm Temperature value can be setted as -20-220°C or
-4.0-428.0° F.
Temperature Setup:
In the "Sensor Setting" interface, press UP or DN to make
the navigation mark to choose "Temperature Sensor", and
press ENT to enter "Temperature Sensor" setting interface.
See the illustration.
(3.1) Unit
Te
MP
erature
ui
T1
T2
Inhibit
Inhibit
Press UP or DN to make the navigation mark to choose "Unit" setting item, and press R or L to choose Unit,
two kinds of Unit:Celsius and Fahrenheit.
(3.2) Alarm Temperature Setup
Press UP or DN select the T1, Press R or L to activate the
setting.lnhibit will change to Active and Alarm temperature
will be shown. If you choose Inhibit, the Alarm temperature
value won't be shown.
Press UP or DN to select "Alarm" setting, press R or L to
set the alarm temperature value. Press UP or DN to set
other items after finishing the setting.