Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E
(3) Throttle Switch setting
It's invalid for setting, the factory default is HOLD switch
which will be shown in the status item. When the Throttle
Hold switch is ON, data under the Throttle Hold can not be
amended until Throttle Hold switch to be OFF, and the hold
status is changed.
Press EXT to exit after setting up finished.
L
Throttle Hold
Hold ::::witc: h
status
111
3.6 Throttle Curve
Throttle Curve are adjusted through 7 points.
Setting method:
Press ENT to enter main menu, Press UP or DN to move navigation mark to select Function Menu. Press
ENT to enter Function Menu. Press UP or DN to select Throttle Curve, Press ENT to enter Throttle Curve
interface.The enquiry dropdown is shown "All servos hold?" If click OK, all the servos will be locked at the
current status, if click Cancel, all the servos will be unlocked at the current status.
Throttle C:urve
Channel
Throttle
Position
pos
0.0
El .
C
J
L I HU H
(1) Channel setting
The default setting is Throttle Channel, and can not reset.
(2) Position selection
Press UP or DN in the "Throttle Curve" setting interface to select "Position", press R or L to select the item
you want to set in the list with Pos 0 and Pos 1.
(3) Exponential Adjustment
Press UP or DN in Throttle Curve interface to move
navigation mark of exponential curve and press R or L
to set the exponential function Off and On. The throttle
curve will be changed smoothly if touching ON, or in
fold line if clicking OFF.
(4) Curve setting
It includes two items: Point and Output.
(4.1) Point setting
Press UP or DN in Throttle Curve interface to select Points setting. Press L to expand a list including seven
points: "Point-L", "Point-1", "Point-2", "Point-M", "Point-3", "Point-4" and "Point-H". Press R or L to select the
point you want to adjust.
(4.2) Status setting
After above setup, press UP or DN to select Status setting, press R or L to set Inhibit and Active. Select Inhibit
if for keeping the current value (the default setting is Inhibit). Select Active for changing the above points'
value.